Application: widely used in power industry, communication, automobile, ship, aircraft manufacturing and other fields.
Application: widely used in power industry, communication, automobile, ship, aircraft manufacturing and other fields.
L thermal shrinkage ratio: 2:1
L initial shrinkage temperature: ≥ + 84 ℃
L complete shrinkage temperature: ≥ + 120 ℃
L working temperature: - 55 ℃ ~ + 125 ℃
L environmental protection, high strength, elasticity and flame retardant
L environmental protection certification: RoHS
performance | index | Test standard: |
tensile strength | ≥8 Mpa | GB/T1040 |
elongation at break | ≥300% | GB/T1040 |
Tensile strength after thermal aging | ≥6.4 Mpa | GB/T1040,GB/T7141 |
Elongation at break after thermal aging | ≥100% | GB/T1040,GB/T7141 |
Radial shrinkage | ≥50% | |
Axial shrinkage | Φ20~Φ30≤5%; Φ40~Φ50≤8%; Φ60以上≤15% | |
thermal shock | No cracking and no flowing | Jb7829 Appendix D (160 ℃) × 4h) |
Low temperature resistance | No cracking | (- 40 ℃) |
Flame retardant test (oxygen index O.I) | ≥28 | GB/T2406 |
Breakdown strength | ≥15kV/mm | GB/T1408.1 |
Volume resistivity | ≥4.3×1014Ω·cm | GB/T1410 |
Hardness (Shore A) | ≤90 | GB 2411 |
*This indicator is applicable to 10kV busbar when conducting this indicator test. The product must be uniformly shrunk on the busbar, and the length of parallel section shall be ≥ 1200mm.
Electrical performance | |||||
project | Company | index | |||
1kV Grade | 10kV Grade | 20kV Grade | 35kV Grade | ||
Power frequency voltage test | kV | 2 | 42 | 50 | 95 |
Lightning impulse voltage test | kV | 4 | 75 | 95 | 185 |
Specification of 1kV continuous busbar protection heat shrinkable sleeve:
Specifications | Applicable busbar (square / round) | Supply inner diameter (mm) | Full reduced size (mm) | Standard packaging M / plate | |
internal diameter | wall thickness | ||||
1kV MPG 30/15 | 30 | 31.5±1.0 | ≤15 | 0.75±0.15 | 25 |
1kV MPG 35/18 | 35 | 36.5±1.5 | ≤18 | 0.75±0.15 | 25 |
1kV MPG 40/20 | 40 | 41.5±1.5 | ≤20 | 0.75±0.15 | 25 |
1kV MPG 45/23 | 45 | 46.5±1.5 | ≤23 | 0.80±0.15 | 25 |
1kV MPG 50/25 | 50 | 51±2.0 | ≤25 | 0.80±0.15 | 25 |
1kV MPG 60/30 | 60 | 60±3.0 | ≤30 | 0.80±0.20 | 25 |
1kV MPG 65/33* | 60 | 65±3.0 | ≤33 | 0.80±0.20 | 25 |
1kV MPG 70/35 | 70 | 70±3.0 | ≤35 | 0.80±0.20 | 25 |
1kV MPG 75/38* | 75 | 75±3.0 | ≤38 | 0.95±0.20 | 25 |
1kV MPG 80/40 | 80/100 | 80±3.0 | ≤40 | 1.00±0.20 | 25 |
1kV MPG 85/43* | 80/100 | 85±3.0 | ≤43 | 1.00±0.20 | 25 |
1kV MPG 90/45 | 100 | 90±4.0 | ≤45 | 1.00±0.20 | 25 |
1kV MPG 100/50 | 100/120 | 100±4.0 | ≤50 | 1.00±0.20 | 25 |
1kV MPG 120/60 | 150 | 120±4.0 | ≤60 | 1.10±0.20 | 25 |
1kV MPG 150/75 | 180 | 150±4.0 | ≤75 | 1.10±0.20 | 25 |
Note: specifications marked with * indicate that they are not in stock and need to be ordered.
Specification of heat shrinkable sleeve for 10kV continuous busbar protection
Specifications | Applicable busbar (square / round) | Supply inner diameter (mm) | Full reduced size (mm) | Standard packaging M / plate | |
internal diameter | wall thickness | ||||
10kV MPG 15/8 | 15/12 | 15±0.8 | ≤8 | 1.80±0.30 | 25 |
10kV MPG 20/10 | 20/15 | 20±0.8 | ≤10 | 1.80±0.30 | 25 |
10kV MPG 25/12 | 25/18 | 25±0.8 | ≤12 | 1.80±0.30 | 25 |
10kV MPG 30/15 | 30/20 | 30±0.8 | ≤15 | 2.00±0.30 | 25 |
10kV MPG 40/20 | 40/30 | 40±1.0 | ≤20 | 2.10±0.30 | 25 |
10kV MPG 50/25 | 50/35 | 50±2.0 | ≤25 | 2.10±0.30 | 25 |
10kV MPG 60/30 | 60/45 | 60±3.0 | ≤30 | 2.10±0.30 | 25 |
10kV MPG 65/33* | 65/45 | 65±3.0 | ≤33 | 2.10±0.30 | 25 |
10kV MPG 70/35 | 70/50 | 70±3.0 | ≤35 | 2.30±0.30 | 25 |
10kV MPG 75/38* | 75/50 | 75±3.0 | ≤38 | 2.30±0.30 | 25 |
10kV MPG 80/40 | 80/55 | 80±3.0 | ≤40 | 2.30±0.30 | 25 |
10kV MPG 85/43* | 80/65 | 85±3.0 | ≤43 | 2.30±0.30 | 25 |
10kV MPG 100/50 | 100/75 | 100±4.0 | ≤50 | 2.40±0.30 | 25 |
10kV MPG 120/60 | 120/85 | 120±4.0 | ≤60 | 2.40±0.30 | 25 |
10kV MPG 150/75 | 150/105 | 150±4.0 | ≤75 | 2.40±0.30 | 25 |
Note: specifications marked with * indicate that no inventory is required and special orders need to be placed.
Specification of heat shrinkable bushing for 20kV continuous busbar protection
Specifications | Performance applicable busbar (square / round) | Supply inner diameter (mm) | Full reduced size (mm) | Standard packaging M / plate | |
internal diameter | wall thickness | ||||
20kV MPG 15/8 | 15/12 | 15±0.8 | ≤8 | 2.30±0.20 | 25 |
20kV MPG 20/10 | 20/15 | 20±0.8 | ≤10 | 2.30±0.20 | 25 |
20kV MPG 25/13 | 25/18 | 25±0.8 | ≤13 | 2.30±0.20 | 25 |
20kV MPG 30/15 | 30/20 | 30±0.8 | ≤15 | 2.30±0.20 | 25 |
20kV MPG 40/20 | 40/30 | 40±1.0 | ≤20 | 2.60±0.30 | 25 |
20kV MPG 50/25 | 50/35 | 50±2.0 | ≤25 | 2.60±0.30 | 25 |
20kV MPG 60/30 | 60/45 | 60±3.0 | ≤30 | 2.60±0.30 | 25 |
20kV MPG 65/33* | 65/45 | 65±3.0 | ≤33 | 2.60±0.30 | 25 |
20kV MPG 70/35 | 70/50 | 70±3.0 | ≤35 | 2.60±0.30 | 25 |
20kV MPG 75/38 | 75/50 | 75±3.0 | ≤38 | 2.60±0.30 | 25 |
20kV MPG 80/40 | 80/55 | 80±3.0 | ≤40 | 2.60±0.30 | 25 |
20kV MPG 85/43* | 80/65 | 85±3.0 | ≤43 | 2.60±0.30 | 25 |
20kV MPG 100/50 | 100/75 | 100±4.0 | ≤50 | 2.60±0.30 | 25 |
20kV MPG 120/60 | 120/85 | 120±4.0 | ≤60 | 2.60±0.30 | 25 |
20kV MPG 150/75 | 150/105 | 150±4.0 | ≤75 | 2.60±0.30 | 25 |
Note: specifications marked with * indicate that they are not in stock and need to be ordered.
Specification of heat shrinkable bushing for 35kV continuous busbar protection:
Specifications | Applicable busbar (square busbar) | Supply inner diameter (mm) | Full reduced size (mm) | Standard packaging M / plate | |
internal diameter | wall thickness | ||||
35kV MPG 15/8 | 15/12 | 15±1.0 | ≤8.0 | 3.30±0.30 | 20 |
35kV MPG 20/10 | 20/15 | 20±1.0 | ≤10.0 | 3.30±0.30 | 20 |
35kV MPG 30/15 | 30 | 30±1.0 | ≤15.0 | 3.30±0.30 | 20 |
35kV MPG 35/18 | 30/40 | 35±1.0 | ≤18.0 | 3.30±0.30 | 20 |
35kV MPG 40/20 | 40 | 40±1.0 | ≤20.0 | 3.30±0.30 | 20 |
35kV MPG 50/25 | 50 | 50±2.0 | ≤25.0 | 3.30±0.30 | 20 |
35kV MPG 60/30 | 60 | 60±2.0 | ≤30.0 | 3.50±0.30 | 20 |
35kV MPG 65/33* | 60/70 | 65±2.0 | ≤33.0 | 3.50±0.30 | 20 |
35kV MPG 70/35 | 70 | 70±2.0 | ≤35.0 | 3.50±0.30 | 20 |
35kV MPG 75/38* | 70/80 | 75±2.0 | ≤38.0 | 3.70±0.30 | 20 |
35kV MPG 80/40 | 80/100 | 80±4.0 | ≤40.0 | 3.70±0.30 | 20 |
35kV MPG 100/50 | 100/120 | 100±4.0 | ≤50.0 | 3.80±0.30 | 20 |
35kV MPG 120/60 | 150 | 120±4.0 | ≤60.0 | 3.80±0.30 | 20 |
35kV MPG 150/75 | 180 | 150±4.0 | ≤75.0 | 3.80±0.30 | 20 |
Note: specifications marked with * indicate that they are not in stock and need to be ordered.
Tel: + 86 0577 61758955
Mobile: + 86 13587882088
Address: No. 13, Xiangzhong West Road, Liushi Town, Yueqing City, Wenzhou City, Zhejiang Province
Copyright©2022 Zhejiang Langdao Electric Co., Ltd ALL 浙ICP备17003169号-1
Tel: + 86 0577 61758955
Mobile: + 86 13587882088
E-mail: lddq@cnlddq.com
Address: No. 13, Xiangzhong West Road, Liushi Town, Yueqing City, Wenzhou City, Zhejiang Province